Search results for "Joint replacement"
showing 10 items of 26 documents
Preferred Outcome Measures Used in Randomized Clinical Trials of Total Knee Replacement Rehabilitation: A Systematic Review.
2020
Objective To determine the most frequently used outcome measures in total knee replacement rehabilitation trials. Literature survey Systematic review of randomized trials searched in five databases: Web of Science, MEDical Literature Analysis and Retrieval System, Physiotherapy Evidence Database, Scopus, and Cochrane Library. Methodology Trials were included if participants underwent total knee replacement rehabilitation and outcome measures were used to assess rehabilitation outcomes. A descriptive synthesis determined the frequency of using outcome measures and preferred assessment time points. Outcomes were classified into eight categories: patient- and clinician-reported function, perfo…
Complex radial head and neck fractures treated with modern locking plate fixation
2019
Background Internal fixation of complex radial head and neck (CRHN) fractures is difficult, and postoperative complications are common. This study evaluated elbow function and patient clinical status after internal fixation of CRHN fractures with modern locking plates. Methods We included 40 patients with 41 fractures (1 bilateral lesion). In 25 patients (61%), a concomitant injury was found. Patients were an average age of 46 years (range, 22-70 years). The mean follow-up time was 36 months (range, 2-70 months). Postoperative assessments included evaluation of range of motion, functional scores, and radiologic findings. We assessed fracture healing, surgical complications, revision surgery…
Comparative, validity and responsiveness of the HOOS-PS and KOOS-PS to the WOMAC physical function subscale in total joint replacement for Osteoarthr…
2009
Udgivelsesdato: 2009-Jul OBJECTIVE: To evaluate the internal consistency of the Hip disability and Osteoarthritis Outcome Score-Physical Function Short-form (HOOS-PS) and the Knee injury and Osteoarthritis Outcome Score-Physical Function Short-form (KOOS-PS) in total hip replacement (THR) and total knee (TKR) replacement. Construct validity and responsiveness were compared to the Western Ontario McMaster Universities' Osteoarthritis Index (WOMAC) Likert 3.0 physical function (PF) subscale and the PF excluding the items in the short measures (PF-exclusions). METHODS: Participants completed the full HOOS or KOOS, measures of fatigue, anxiety, depression and the Chronic Pain Grade (CPG) pre-su…
Komplikationen der Redon-drainage each hüftgelenksersatzoperationen — eine analyse der ursachen
1989
Die Redon-Drainage hat die Operationsresultate entscheidend verbessert. Jedoch sind einige Komplikationen durch das Hochvakuum-System nicht zu verhindern, sie sind vielmehr sogar dadurch bedingt. Redon-Flaschen als Einwegprodukte entsprechen haufig nicht den gestellten Anforderungen. Es handelt sich nur um ein zeitweise “geschlossenes” System mit hohem Infektionsrisiko bei Flaschenwechsel. Nach Entwicklung einer vom Legen bis zum Ziehen der Drains stets geschlossenen Drainage wurden in einer prospektiven Studie nach Huftgelenksersatzoperationen verschiedene systembedingte Faktoren analysiert. Verglichen wurden die Redon-Hochvakuum-Drainage sowie ein kontinuierlich ansteigender Unterdruck bi…
Pain monitoring and management in a rehabilitation setting after total joint replacement
2018
Abstract Total hip replacement (THR) and, particularly, total knee replacement (TKR), are painful surgical procedures. Effective postoperative pain management leads to a better and earlier functional recovery and prevents chronic pain. Studies on the control of pain during the postoperative rehabilitation period are not common. The aim of this study is to present results of a perioperative anesthetic protocol, and a pain treatment protocol in use in the Orthopaedic and the Rehabilitation intensive units of our Hospital. 100 patients (50 THR and 50 TKR) were retrospectively included in this observational study. Numeric Rating Scale (NRS) for pain at rest registered in the clinical sheet was …
Reduced-dose computed tomography is the most accurate method to measure ceramic hip resurfacing cup version
2020
Background: A precise assessment of cup version after hip resurfacing is generally requested, especially in clinical trials or in case of complications. Aims: To identify which diagnostic imaging modality, between AP pelvis X-rays, the AP Pelvis CT Scout image and reduced-dose axial CT scan, is the most precise to assess cup version of an all-ceramic hip resurfacing implant in a first-in-human clinical trial. Methods: We retrospectively assessed the cup version of the first 20 patients who underwent an experimental all-ceramic hip resurfacing on AP pelvis X-rays (0.8 mSv of radiation), AP pelvis CT scout images (0.016 mSv) and axial CT slices performed using a reduced dose protocol (0.3 mSv…
Factors associated with the orthopaedic surgeon's decision to recommend total joint replacement in hip and knee osteoarthritis: an international cros…
2018
Summary Objective To determine factors associated with orthopaedic surgeons' decision to recommend total joint replacement (TJR) in people with knee and hip osteoarthritis (OA). Design Cross-sectional study in eleven countries. For consecutive outpatients with definite hip or knee OA consulting an orthopaedic surgeon, the surgeon's indication of TJR was collected, as well as patients' characteristics including comorbidities and social situation, OA symptom duration, pain, stiffness and function (Western Ontario and McMaster Universities Osteoarthritis Index [WOMAC]), joint-specific quality of life, Osteoarthritis Research Society International (OARSI) joint space narrowing (JSN) radiographi…
New aspects in the histological examination of polyethylene wear particles in failed total joint replacements.
2002
The most important long-term complication in total joint replacements is aseptic osteolysis. Wear particles such as polyethylene (PE) debris are considered to be one of the causes that play a central role. Several studies indicated that PE can be visualised in paraffin-embedded tissue sections not only by polarised light, but also after oil red staining. To determine whether oil red staining enables sensitive detection of PE, we examined staining of mechanically-produced PE particles by oil red. Furthermore, we studied oil red staining of paraffin-embedded tissue specimens of patients with failed uncemented and cemented total knee and hip prostheses. We applied double labelling of sections …
Tissue evacuated during joint replacement procedure as a source of mononuclear cells.
2017
Background Different cell populations from bone marrow were used in various clinical trials for cardiac diseases during last decade. Four clinical studies are ongoing in our institution and enroll patients with cardiac diseases, coronary disease, type 2 diabetes, and osteoarthritis. The density gradient is used to separate bone marrow mononuclear cells. Joint replacement procedures were associated with significant loss of tissue. Usually, excess tissue as bone marrow, peripheral blood and fat are removed to clean operation site. The aim of this study is to prove whether removed tissue during joint replacement procedure can be considered as a significant source of mononuclear cells. Methods …
The Use of Computer Navigation in Total Hip Arthroplasty Is Associated with a Reduced Rate of Revision for Dislocation
2021
BACKGROUND: The use of computer navigation has been shown to produce more accurate cup positioning when compared with non-navigated total hip arthroplasty (THA), but so far there is only limited evidence to show its effect on clinical outcomes. The present study analyzed data from the Australian Orthopaedic Association National Joint Replacement Registry to assess the impact of computer navigation on the rates of all-cause revision and revision for dislocation following THA. METHODS: Data for all non-navigated and navigated primary THAs performed for osteoarthritis in Australia from January 1, 2009, to December 31, 2019, were examined to assess the rate of revision. We analyzed the effects …